Product characteristics | |||||||
---|---|---|---|---|---|---|---|
Output signal | switching signal | ||||||
Measuring range |
| ||||||
Process connection | threaded connection 1/4″ NPT internal thread | ||||||
Application | |||||||
Application | for industrial applications | ||||||
Media | liquids and gases | ||||||
Conditionally suitable for | use in gases at pressures > 25 bar only on request | ||||||
Medium temperature [°C] | -25…80 | ||||||
Min. bursting pressure |
| ||||||
Pressure rating |
| ||||||
Type of pressure | relative pressure | ||||||
Electrical data | |||||||
Operating voltage tolerance [%] | 5…10 | ||||||
Operating voltage [V] | 85…265 AC | ||||||
Nominal voltage AC [V] | < 250 | ||||||
Current consumption [mA] | < 10 | ||||||
Min. insulation resistance [MΩ] | 100; (500 V DC) | ||||||
Protection class | II | ||||||
Reverse polarity protection | no | ||||||
Power-on delay time [s] | 0.2 | ||||||
Integrated watchdog | yes | ||||||
Inputs / outputs | |||||||
Number of inputs and outputs | Number of digital outputs: 1 | ||||||
Outputs | |||||||
Total number of outputs | 1 | ||||||
Output signal | switching signal | ||||||
Electrical design | Triac | ||||||
Number of digital outputs | 1 | ||||||
Output function | normally open / normally closed; (parameterisable) | ||||||
Max. voltage drop switching output AC [V] | 2 | ||||||
Permanent current rating of switching output AC [mA] | 250; ((…70 °C) 1000 (…60 °C) 1500 (…45 °C) 2500 (…20 °C)) | ||||||
Switching frequency AC [Hz] | < 160 | ||||||
Short-circuit proof | no | ||||||
Overload protection | no | ||||||
Measuring/setting range | |||||||
Measuring range |
| ||||||
Set point SP |
| ||||||
Reset point rP |
| ||||||
In steps of |
| ||||||
Accuracy / deviations | |||||||
Switch point accuracy [% of the span] | < ± 1,0 | ||||||
Repeatability [% of the span] | < ± 0,1; (with temperature fluctuations < 10 K) | ||||||
Linearity deviation [% of the span] | < ± 0,5 | ||||||
Hysteresis deviation [% of the span] | < ± 0,1 | ||||||
Long-term stability [% of the span] | < ± 0,1; (per year) | ||||||
Temperature coefficient zero point [% of the span / 10 K] | < ± 0,2; (-25…80 °C) | ||||||
Temperature coefficient span [% of the span / 10 K] | < ± 0,3; (-25…80 °C) | ||||||
Response times | |||||||
Delay time programmable dS, dr [s] | 0, 0,2,…10, 11,…50 | ||||||
Damping for the switching output dAP [s] | 0…4 | ||||||
Software / programming | |||||||
Adjustment of the switch point | programming button | ||||||
Parameter setting options | hysteresis / window; normally open / normally closed; switch-on/switch-off delay; Damping; adaptation of displayed values; display can be rotated and switched off; Display unit | ||||||
Operating conditions | |||||||
Ambient temperature [°C] | -25…80 | ||||||
Storage temperature [°C] | -40…100 | ||||||
Protection | IP 67 | ||||||
Mechanical data | |||||||
Weight [g] | 391 | ||||||
Materials | stainless steel (1.4301 / 304); PC; PBT; PA; FKM | ||||||
Materials (wetted parts) | stainless steel (1.4305 / 303); ceramics; FKM | ||||||
Min. pressure cycles | 100 million | ||||||
Process connection | threaded connection 1/4″ NPT internal thread | ||||||
Restrictor element integrated | no (can be retrofitted) | ||||||
Displays / operating elements | |||||||
Display |
| ||||||
Electrical connection | |||||||
Required protection | miniature fuse to IEC60127-2 sheet 1; ≤ 5 A; fast acting | ||||||
Remarks | |||||||
Remarks |
| ||||||
Pack quantity | 1 pcs. | ||||||
Electrical connection | |||||||
Connection | Connector: 1 x 1/2″ |