Product characteristics | |||||||||
---|---|---|---|---|---|---|---|---|---|
Output signal | switching signal; analogue signal; (configurable) | ||||||||
Measuring range [bar] | -1…150 | ||||||||
Process connection | threaded connection G 1 external thread sealing cone | ||||||||
Application | |||||||||
Special feature | Gold-plated contacts | ||||||||
Installation | freely rotatable housing 350° | ||||||||
Media | liquids and gases | ||||||||
Conditionally suitable for | use in gases at pressures > 25 bar only on request | ||||||||
Medium temperature [°C] | -25…125; (145 max. 1h) | ||||||||
Min. bursting pressure [bar] | 650 | ||||||||
Pressure rating [bar] | 200 | ||||||||
Type of pressure | relative pressure; vacuum | ||||||||
No dead space | yes | ||||||||
Electrical data | |||||||||
Operating voltage [V] | 18…32 DC | ||||||||
Current consumption [mA] | < 50 | ||||||||
Min. insulation resistance [MΩ] | 100; (500 V DC) | ||||||||
Protection class | III | ||||||||
Reverse polarity protection | yes | ||||||||
Power-on delay time [s] | 0.5 | ||||||||
Integrated watchdog | yes | ||||||||
Inputs / outputs | |||||||||
Number of inputs and outputs | Number of digital outputs: 1; Number of analogue outputs: 1 | ||||||||
Outputs | |||||||||
Total number of outputs | 2 | ||||||||
Output signal | switching signal; analogue signal; (configurable) | ||||||||
Electrical design | PNP/NPN | ||||||||
Number of digital outputs | 1 | ||||||||
Output function | normally open / normally closed; (parameterisable) | ||||||||
Max. voltage drop switching output DC [V] | 2 | ||||||||
Permanent current rating of switching output DC [mA] | 250 | ||||||||
Switching frequency DC [Hz] | 6 | ||||||||
Number of analogue outputs | 1 | ||||||||
Analogue current output [mA] | 4…20, invertible; (scalable 1:4) | ||||||||
Max. load [Ω] | (Ub – 10 V) / 20 mA | ||||||||
Analogue voltage output [V] | 0…10, invertible; (scalable 1:4) | ||||||||
Min. load resistance [Ω] | 2000 | ||||||||
Short-circuit protection | yes | ||||||||
Type of short-circuit protection | pulsed | ||||||||
Overload protection | yes | ||||||||
Measuring/setting range | |||||||||
Measuring range [bar] | -1…150 | ||||||||
Set point SP [bar] | -0.8…150 | ||||||||
Reset point rP [bar] | -1…149.8 | ||||||||
Analogue start point [bar] | -1…112.5 | ||||||||
Analogue end point [bar] | 36.5…150 | ||||||||
In steps of [bar] | 0.1 | ||||||||
Accuracy / deviations | |||||||||
Switch point accuracy [% of the span] | < ± 0,5; (Turn down 1:1) | ||||||||
Repeatability [% of the span] | < ± 0,1; (with temperature fluctuations < 10 K; Turn down 1:1) | ||||||||
Characteristics deviation [% of the span] | < ± 0,5; (Turn down 1:1 linearity, incl. hysteresis and repeatability limit value setting to DIN 16086) | ||||||||
Linearity deviation [% of the span] | < ± 0,15; (Turn down 1:1) | ||||||||
Hysteresis deviation [% of the span] | < ± 0,15; (Turn down 1:1) | ||||||||
Long-term stability [% of the span] | < ± 0,1; (Turn down 1:1; per year) | ||||||||
Temperature coefficient zero point [% of the span / 10 K] | < ± 0,05; (0…70 °C) | ||||||||
Temperature coefficient span [% of the span / 10 K] | < ± 0,15; (0…70 °C) | ||||||||
Response times | |||||||||
Response time [ms] | < 100 | ||||||||
Damping for the switching output dAP [s] | 0.1…100 | ||||||||
Damping for the analogue output dAA [s] | 0.1…100 | ||||||||
Max. response time analogue output [ms] | 100 | ||||||||
Software / programming | |||||||||
Parameter setting options | hysteresis / window; normally open / normally closed; switching logic; current/voltage output; Damping; adaptation of displayed values; display can be rotated and switched off; Display unit; zero point; span | ||||||||
Operating conditions | |||||||||
Ambient temperature [°C] | -25…80 | ||||||||
Storage temperature [°C] | -40…100 | ||||||||
Protection | IP 67; IP 69K | ||||||||
Mechanical data | |||||||||
Weight [g] | 450 | ||||||||
Materials | stainless steel (1.4404 / 316L); PC; PBT; PEI; FKM; PTFE | ||||||||
Materials (wetted parts) | stainless steel (1.4435 / 316L); ceramics; PTFE | ||||||||
Min. pressure cycles | 100 million | ||||||||
Process connection | threaded connection G 1 external thread sealing cone | ||||||||
Displays / operating elements | |||||||||
Display |
| ||||||||
Display unit | bar; psi; MPa; % of the span | ||||||||
Remarks | |||||||||
Pack quantity | 1 pcs. | ||||||||
Electrical connection | |||||||||
Connection | Connector: 1 x M12; Contacts: gold-plated |