Product characteristics | ||||
---|---|---|---|---|
Output function | normally open / normally closed; (selectable) | |||
Sensing range [mm] | 40 | |||
Housing | rectangular | |||
Electrical data | ||||
Operating voltage [V] | 20…250 AC/DC | |||
Protection class | II | |||
Reverse polarity protection | no | |||
Outputs | ||||
Output function | normally open / normally closed; (selectable) | |||
Max. voltage drop switching output DC [V] | 6 | |||
Max. voltage drop switching output AC [V] | 6.5 | |||
Minimum load current [mA] | 5 | |||
Max. leakage current [mA] | 2.5 (250 V AC) / 1.3 (110 V AC) / 0.8 (24 V DC) | |||
Permanent current rating of switching output AC [mA] | 250; (350 (…50 °C)) | |||
Permanent current rating of switching output DC [mA] | 100 | |||
Short-time current rating of switching output [mA] | 2200; (20 ms / 0,5 Hz) | |||
Switching frequency AC [Hz] | 10 | |||
Switching frequency DC [Hz] | 10 | |||
Short-circuit proof | no | |||
Overload protection | no | |||
Detection zone | ||||
Sensing range [mm] | 40 | |||
Sensing range adjustable | yes | |||
Factory setting sensing range [mm] | 40 | |||
Real sensing range Sr [mm] | 40 ± 10 % | |||
Operating distance [mm] | 0…32.4 | |||
Accuracy / deviations | ||||
Correction factor | steel: 1 / stainless steel: 0.7 / brass: 0.4 / aluminium: 0.3 / copper: 0.2 | |||
Hysteresis [% of Sr] | 1…15 | |||
Switch point drift [% of Sr] | -10…10 | |||
Operating conditions | ||||
Ambient temperature [°C] | -25…80 | |||
Protection | IP 65 | |||
Mechanical data | ||||
Weight [g] | 274.5 | |||
Housing | rectangular | |||
Mounting | non-flush mountable | |||
Materials | PPE | |||
Displays / operating elements | ||||
Display |
| |||
Electrical connection | ||||
Required protection | miniature fuse to IEC60127-2 sheet 1; ≤ 2 A; fast acting | |||
Accessories | ||||
Accessories (supplied) |
| |||
Remarks | ||||
Remarks |
| |||
Pack quantity | 1 pcs. | |||
Electrical connection | ||||
Connection | terminals: …2.5 mm²; Cable sheath: Ø 7…13 mm |