Product characteristics | |||||
---|---|---|---|---|---|
Output function | normally open | ||||
Sensing range [mm] | 35 | ||||
Housing | rectangular | ||||
Application | |||||
Special feature | Increased sensing range | ||||
Electrical data | |||||
Frequency AC [Hz] | 47…63 | ||||
Operating voltage [V] | 20…140 AC / 10…140 DC | ||||
Protection class | I | ||||
Reverse polarity protection | yes | ||||
Outputs | |||||
Output function | normally open | ||||
Max. voltage drop switching output DC [V] | 5.5 | ||||
Max. voltage drop switching output AC [V] | 5.5 | ||||
Minimum load current [mA] | 5.5 | ||||
Max. leakage current [mA] | 1.7 (140 V AC/DC) | ||||
Permanent current rating of switching output AC [mA] | 450 | ||||
Permanent current rating of switching output DC [mA] | 450 | ||||
Short-time current rating of switching output [mA] | 2200; (20 ms / 0,5 Hz) | ||||
Switching frequency AC [Hz] | 25 | ||||
Switching frequency DC [Hz] | 100 | ||||
Short-circuit protection | yes | ||||
Type of short-circuit protection | pulsed | ||||
Overload protection | yes | ||||
Detection zone | |||||
Sensing range [mm] | 35 | ||||
Operating distance [mm] | 0…28.3 | ||||
Increased sensing range | yes | ||||
Accuracy / deviations | |||||
Correction factor | steel: 1 / stainless steel: 0.7 / brass: 0.4 / aluminium: 0.4 / copper: 0.3 | ||||
Hysteresis [% of Sr] | 3…15 | ||||
Operating conditions | |||||
Ambient temperature [°C] | -25…70 | ||||
Protection | IP 67 | ||||
Mechanical data | |||||
Weight [g] | 266.5 | ||||
Housing | rectangular | ||||
Mounting | non-flush mountable | ||||
Materials | PPE; connector housing: brass; clamp: diecast zinc | ||||
Displays / operating elements | |||||
Display |
| ||||
Remarks | |||||
Remarks |
| ||||
Pack quantity | 1 pcs. | ||||
Electrical connection – plug | |||||
Connector: 1 x 7/8″ |