Product characteristics | |
---|---|
Electrical design | NAMUR |
Output function | normally closed |
Sensing range [mm] | 4 |
Housing | rectangular |
Dimensions [mm] | 40 x 12 x 26 |
Electrical data | |
Connection to switching amplifiers | yes |
Switching amplifiers | connection to certified intrinsically safe circuits with the max. values: U = 15 V / I = 50 mA / P = 120 mW |
Nominal voltage DC [V] | 8.2; (1kΩ) |
Supply voltage DC [V] | 7.5…30; (when used outside the hazardous area) |
Current consumption [mA] | < 1; (disabled; conductive: > 2,1) |
Protection class | II |
Outputs | |
Electrical design | NAMUR |
Output function | normally closed |
Permanent current rating of switching output DC [mA] | 30; (when used outside the hazardous area) |
Switching frequency DC [Hz] | 400 |
Detection zone | |
Sensing range [mm] | 4 |
Real sensing range Sr [mm] | 4 ± 10 % |
Accuracy / deviations | |
Correction factor | steel: 1 / stainless steel: 0.7 / brass: 0.5 / aluminium: 0.4 / copper: 0.3 |
Hysteresis [% of Sr] | 1…15 |
Switch point drift [% of Sr] | -10…10 |
Operating conditions | |
Ambient temperature [°C] | -20…80 |
Protection | IP 67 |
Safety classification | |
Max. internal capacitance [nF] | 112 |
Max. internal inductance [µH] | 143 |
Mechanical data | |
Weight [g] | 447 |
Housing | rectangular |
Mounting | non-flush mountable |
Dimensions [mm] | 40 x 12 x 26 |
Materials | PBT |
Remarks | |
Pack quantity | 1 pcs. |
Electrical connection | |
Connection | Cable: 10 m, PVC; 2 x 0.5 mm² |