Product characteristics | ||||||
---|---|---|---|---|---|---|
Number of inputs and outputs | Number of digital outputs: 2; Number of analogue outputs: 1 | |||||
Measuring range |
| |||||
Process connection | threaded connection G 1 internal thread | |||||
Application | ||||||
Application | for industrial applications | |||||
Installation | Adjustable to inside pipe diameters; ( 14…254 mm) | |||||
Media | compressed air | |||||
Medium temperature [°C] | -10…60 | |||||
Min. bursting pressure [bar] | 64 | |||||
Min. bursting pressure [MPa] | 6.4 | |||||
Pressure rating [bar] | 16 | |||||
Pressure rating [Mpa] | 1.6 | |||||
Electrical data | ||||||
Operating voltage [V] | 18…30 DC; (according to EN 50178 SELV/PELV) | |||||
Current consumption [mA] | < 80 | |||||
Protection class | III | |||||
Reverse polarity protection | yes | |||||
Power-on delay time [s] | 1 | |||||
Inputs / outputs | ||||||
Number of inputs and outputs | Number of digital outputs: 2; Number of analogue outputs: 1 | |||||
Inputs | ||||||
Inputs | counter reset | |||||
Outputs | ||||||
Output signal | switching signal; analogue signal; pulse signal; IO-Link; (configurable) | |||||
Electrical design | PNP/NPN | |||||
Number of digital outputs | 2 | |||||
Output function | normally open / normally closed; (parameterisable) | |||||
Max. voltage drop switching output DC [V] | 2.5 | |||||
Permanent current rating of switching output DC [mA] | 150; (per output) | |||||
Number of analogue outputs | 1 | |||||
Analogue current output [mA] | 4…20; (scalable) | |||||
Max. load [Ω] | 500 | |||||
Pulse output | consumed quantity meter | |||||
Short-circuit protection | yes | |||||
Type of short-circuit protection | pulsed | |||||
Overload protection | yes | |||||
Measuring/setting range | ||||||
Measuring range |
| |||||
Display range |
| |||||
Resolution |
| |||||
Set point SP |
| |||||
Reset point rP |
| |||||
Analogue start point ASP |
| |||||
Analogue end point AEP |
| |||||
Low flow cut-off LFC |
| |||||
In steps of |
| |||||
Pressure monitoring | ||||||
Measuring range [bar] | -1…16 | |||||
Display range [bar] | -1…20 | |||||
Resolution [bar] | 0.05 | |||||
Set point SP [bar] | -0.92…16 | |||||
Reset point rP [bar] | -1…15.92 | |||||
Analogue start point [bar] | -1…12.8 | |||||
Analogue end point [bar] | 2.2…16 | |||||
In steps of [bar] | 0.01 | |||||
Volumetric flow quantity monitoring | ||||||
Measuring range |
| |||||
Display range |
| |||||
Set point SP |
| |||||
Pulse value |
| |||||
In steps of |
| |||||
Pulse length [s] | 0.001…2 | |||||
Temperature monitoring | ||||||
Measuring range |
| |||||
Display range |
| |||||
Resolution |
| |||||
Set point SP |
| |||||
Reset point rP |
| |||||
Analogue start point |
| |||||
Analogue end point |
| |||||
In steps of |
| |||||
Accuracy / deviations | ||||||
Temperature coefficient [1/K] | ± 0,07 % MW | |||||
Accuracy (in the measuring range) | ± (6 % MW + 0,6 % MEW); (reference conditions: diA = 73 mm; inlet pipe length >= 3 m; outlet pipe length >= 0,5 m; reference temperature : 20…25 °C; standard volume flow: 50…850 Nm³/h) | |||||
Repeatability | ± 1,5 % MW | |||||
Pressure monitoring | ||||||
Repeatability [% of the final value] | ± 0,2 | |||||
Characteristics deviation [% of the final value] | < ± 0,5; (BFSL = Best Fit Straight Line) | |||||
Greatest TEMPCO of the span [% MEW / 10 K] | ± 0,15 | |||||
Greatest TEMPCO of the zero point [% MEW / 10 K] | ± 0,25 | |||||
Temperature monitoring | ||||||
Accuracy [K] | ± 0,5; (medium flow in the limit area of the flow measurement range) | |||||
Response times | ||||||
Response time [s] | 0.1; (dAP = 0) | |||||
Damping for the switching output dAP [s] | 0…5 | |||||
Pressure monitoring | ||||||
Response time [s] | 0.05 | |||||
Temperature monitoring | ||||||
Dynamic response T05 / T09 [s] | T09 = 0,5 | |||||
Software / programming | ||||||
Parameter setting options | hysteresis / window; normally open / normally closed; current/pulse output; display can be rotated and switched off; Display unit; totaliser | |||||
Interfaces | ||||||
Communication interface | IO-Link | |||||
Transmission type | COM2 (38,4 kBaud) | |||||
IO-Link revision | 1.1 | |||||
SDCI standard | IEC 61131-9 CDV | |||||
Profiles | Digital Measuring Sensor (0x800A), Identification and Diagnosis (0x4000) | |||||
SIO mode | yes | |||||
Required master port type | A | |||||
Process data analogue | 8 | |||||
Process data binary | 2 | |||||
Min. process cycle time [ms] | 7.2 | |||||
Supported DeviceIDs |
| |||||
Operating conditions | ||||||
Ambient temperature [°C] | 0…60 | |||||
Storage temperature [°C] | -20…85 | |||||
Max. relative air humidity [%] | 90 | |||||
Protection | IP 65; IP 67 | |||||
Mechanical data | ||||||
Weight [g] | 408.3 | |||||
Materials | PBT+PC-GF30; PPS GF40; stainless steel (1.4301 / 304); stainless steel (1.4305 / 303); stainless steel (1.4404 / 316L); FKM | |||||
Materials (wetted parts) | stainless steel (1.4301 / 304); stainless steel (1.4404 / 316L) ; FKM; ceramics glass passivated; PPS GF40; Al2O3 (ceramics); acrylate | |||||
Process connection | threaded connection G 1 internal thread | |||||
Displays / operating elements | ||||||
Display |
| |||||
Remarks | ||||||
Remarks |
| |||||
Pack quantity | 1 pcs. | |||||
Electrical connection | ||||||
Connection | Connector: 1 x M12 |