Product characteristics | |||||
---|---|---|---|---|---|
Electrical design | PNP | ||||
Output function | 2 x OSSD (A1 and A2) | ||||
Enable zone [mm] | > 10 | ||||
Housing | threaded type | ||||
Dimensions [mm] | M18 x 1 / L = 86.5 | ||||
Application | |||||
Special feature | Gold-plated contacts | ||||
Type of operation | continuous operation (maintenance-free) | ||||
Application | industrial application | ||||
Electrical data | |||||
Operating voltage [V] | 10…30 DC | ||||
Rated insulation voltage [V] | 30 | ||||
Current consumption [mA] | < 30 | ||||
Protection class | III | ||||
Reverse polarity protection | yes | ||||
Max. power-on delay time [ms] | 1000 | ||||
Outputs | |||||
Electrical design | PNP | ||||
Output function | 2 x OSSD (A1 and A2) | ||||
Max. voltage drop switching output DC [V] | 2.5; (30 mA) | ||||
Minimum load current [mA] | 2 | ||||
Permanent current rating of switching output DC [mA] | 50 | ||||
Output data | Interface type C class 1 | ||||
Output voltage at 24 V | compatible with EN 61131-2 inputs type 1, 2 | ||||
Short-circuit protection | yes | ||||
Max. capacitive load CL_max [nF] | 20 | ||||
Detection zone | |||||
Enable zone [mm] | > 10 | ||||
Safe switching-off distance s(ar) [mm] | < 5 | ||||
Response times | |||||
Response time to safety request [ms] | 5 | ||||
Response time when approaching the enable zone [ms] | 5 | ||||
Risk time (response time for safety-related faults) [ms] | 45 | ||||
Operating conditions | |||||
Applications | class C to EN 60654-1 weatherproof application | ||||
Ambient temperature [°C] | -25…70 | ||||
Note on ambient temperature |
| ||||
Ambient temperature [°C] | 10…40 | ||||
Note on ambient temperature |
| ||||
Rate of temperature change [K/min] | 0.5 | ||||
Max. relative air humidity [%] | briefly: 5…95 %; permanent: 5…70 % | ||||
Air pressure [kPa] | 80…106 | ||||
Max. height above sea level [m] | 2000 | ||||
Ionising radiation | not permissible | ||||
Salt spray | IEC 60068-2-11 | ||||
Protection | IP 65; IP 67 | ||||
Safety classification | |||||
ISO 13849-1 | category 2, PL d | ||||
IEC 61508 | SIL 2 | ||||
IEC 62061 | SIL cl 2 | ||||
Mission time TM [h] | ≤ 175200 | ||||
Mission time TM (additional indication) |
| ||||
Safety-related reliability PFHD [1/h] | < 1.0E-07 | ||||
Mechanical data | |||||
Weight [g] | 162.8 | ||||
Housing | threaded type | ||||
Mounting | flush mountable | ||||
Dimensions [mm] | M18 x 1 / L = 86.5 | ||||
Thread designation | M18 x 1 | ||||
Materials | brass white bronze coated; PBT | ||||
Displays / operating elements | |||||
Display |
| ||||
Accessories | |||||
Accessories (supplied) |
| ||||
Remarks | |||||
Remarks |
| ||||
Pack quantity | 1 pcs. | ||||
Electrical connection – plug | |||||
Connection | Connector: 1 x M12; Contacts: gold-plated |