Product characteristics | |||||||||
---|---|---|---|---|---|---|---|---|---|
Number of inputs and outputs | Number of digital outputs: 4 | ||||||||
Probe length L [mm] | 100…1600 | ||||||||
Process connection | G 3/4 external thread | ||||||||
Application | |||||||||
Special feature | Gold-plated contacts | ||||||||
Installation | Operation only in conjunction with rod and coaxial pipe. | ||||||||
Media | hydrous coolants; oils; oil-based media; water; media similar to water | ||||||||
Dielectric constant of the medium | ≥ 2 | ||||||||
Cannot be used for | See the operating instructions, chapter “Function and features”. | ||||||||
Medium temperature [°C] | 0…80 | ||||||||
Tank pressure [bar] | -0.5…4 | ||||||||
Electrical data | |||||||||
Operating voltage [V] | 18…30 DC | ||||||||
Current consumption [mA] | < 65 | ||||||||
Protection class | III | ||||||||
Reverse polarity protection | yes | ||||||||
Power-on delay time [s] | < 3 | ||||||||
Inputs / outputs | |||||||||
Number of inputs and outputs | Number of digital outputs: 4 | ||||||||
Outputs | |||||||||
Total number of outputs | 4 | ||||||||
Output signal | switching signal | ||||||||
Electrical design | PNP | ||||||||
Number of digital outputs | 4 | ||||||||
Output function | normally open / normally closed; (parameterisable) | ||||||||
Max. voltage drop switching output DC [V] | 2.5 | ||||||||
Permanent current rating of switching output DC [mA] | 200 | ||||||||
Short-circuit protection | yes | ||||||||
Type of short-circuit protection | thermal, pulsed | ||||||||
Overload protection | yes | ||||||||
Measuring/setting range | |||||||||
Probe length L [mm] | 100…1600 | ||||||||
Active range A [mm] | L-40 (L-60); (when set to oil and oil based media) | ||||||||
Inactive range I1 / I2 [mm] | 30 / 10 (30); (when set to oil and oil based media) | ||||||||
Setting range | |||||||||
Set point SP [mm] | ≥ 15 (35) / ≤ L-30 | ||||||||
Note on setpoint SP |
| ||||||||
Reset point rP [mm] | ≥ 10 (30) / ≤ L-35 | ||||||||
Note on reset point rP |
| ||||||||
In steps of [mm] | 5 | ||||||||
Hysteresis [mm] | > 5 | ||||||||
Overflow switch point OP [mm] | 70…L-30 | ||||||||
Hysteresis, OP [mm] | 10 | ||||||||
Accuracy / deviations | |||||||||
Repeatability [mm] | ± 5 | ||||||||
Switch point accuracy [mm] | ± (15 + 0,5 % ); (% of the final value of the measuring range: L – 30 mm) | ||||||||
Operating conditions | |||||||||
Ambient temperature [°C] | 0…60 | ||||||||
Storage temperature [°C] | -25…80 | ||||||||
Protection | IP 67 | ||||||||
Mechanical data | |||||||||
Weight [g] | 402 | ||||||||
Materials | stainless steel (1.4404 / 316L); stainless steel (1.4301 / 304); FKM; PBT-GF20; PC; PEI; TPV | ||||||||
Materials (wetted parts) | stainless steel (1.4305 / 303); probe connection: stainless steel (1.4435 / 316L); PTFE; FKM; Sealing: NBR-PPTA 20 | ||||||||
Process connection | G 3/4 external thread | ||||||||
Displays / operating elements | |||||||||
Display |
| ||||||||
Remarks | |||||||||
Notes | For 8-pole sockets the core colours are not standardised.; Please note the wiring of the sensor and the sockets (see data sheet). | ||||||||
Pack quantity | 1 pcs. | ||||||||
Electrical connection | |||||||||
Connection | Connector: 1 x M12; Contacts: gold-plated |