Product characteristics | |||||
---|---|---|---|---|---|
Number of inputs and outputs | Number of digital outputs: 1; Number of analogue outputs: 1 | ||||
Factory setting | hydrous media; probe length L = 400 mm | ||||
Probe length L [mm] | 100…1600 | ||||
Process connection | G 3/4 external thread | ||||
Application | |||||
Special feature | Gold-plated contacts | ||||
Media | Liquids | ||||
Dielectric constant of the medium | ≥ 1,8; (for media with a dielectric constant of 1.8…5 (e.g. oils), a coaxial pipe is needed for operation) | ||||
Recommended media | water; hydrous media; oils; oil-based media | ||||
Cannot be used for | See the operating instructions, chapter “Function and features”. | ||||
Medium temperature [°C] | -25…80; (90 < 1 h) | ||||
Tank pressure [bar] | -1…16 | ||||
Electrical data | |||||
Operating voltage [V] | 18…30 DC | ||||
Current consumption [mA] | < 25 | ||||
Protection class | III | ||||
Reverse polarity protection | yes | ||||
Power-on delay time [s] | < 3 | ||||
Inputs / outputs | |||||
Number of inputs and outputs | Number of digital outputs: 1; Number of analogue outputs: 1 | ||||
Outputs | |||||
Total number of outputs | 2 | ||||
Output signal | analogue signal; IO-Link | ||||
Electrical design | PNP | ||||
Number of digital outputs | 1 | ||||
Number of analogue outputs | 1 | ||||
Analogue current output [mA] | 4…20, invertible | ||||
Max. load [Ω] | 500 | ||||
Analogue voltage output [V] | 0…10, invertible | ||||
Min. load resistance [Ω] | 2000 | ||||
Short-circuit protection | yes | ||||
Type of short-circuit protection | thermal, pulsed | ||||
Overload protection | yes | ||||
Measuring/setting range | |||||
Factory setting | hydrous media; probe length L = 400 mm | ||||
Probe length L [mm] | 100…1600 | ||||
Active range A [mm] | L-40; (when set to oil and oil based media: L-60) | ||||
Inactive range I1 / I2 [mm] | 30 / 10; (when set to oil and oil based media: 30 / 30) | ||||
Sampling rate [Hz] | 4 | ||||
Accuracy / deviations | |||||
Repeatability [mm] | ± 5 | ||||
Measuring error [mm] | ± 7 | ||||
Offset error [mm] | 5 | ||||
Resolution [mm] | 1 | ||||
Zero signal (voltage) [V] | 0 | ||||
Zero signal (current) [mA] | 4 | ||||
Full signal (voltage) [V] | 10 | ||||
Full signal (current) [mA] | 20 | ||||
Temperature drift per 10 K | ± 0.2 % | ||||
Interfaces | |||||
Communication interface | IO-Link | ||||
Transmission type | COM2 (38,4 kBaud) | ||||
IO-Link revision | 1.1 | ||||
SDCI standard | IEC 61131-9 CDV | ||||
Profiles | no profile | ||||
SIO mode | no | ||||
Required master port type | A | ||||
Process data analogue | 1 | ||||
Min. process cycle time [ms] | 2.3 | ||||
Supported DeviceIDs |
| ||||
Operating conditions | |||||
Ambient temperature [°C] | -25…60 | ||||
Storage temperature [°C] | -40…85 | ||||
Protection | IP 68; IP 69K; (7 days / 1 m water depth / 0.1 bar: IP 68) | ||||
Mechanical data | |||||
Weight [g] | 469 | ||||
Materials | stainless steel (1.4301 / 304); stainless steel (1.4404 / 316L); FKM; PEI | ||||
Materials (wetted parts) | stainless steel (1.4305 / 303); probe connection: stainless steel (1.4435 / 316L); PTFE; FKM; Sealing: NBR reinforced fibre | ||||
Process connection | G 3/4 external thread | ||||
Remarks | |||||
Pack quantity | 1 pcs. | ||||
Electrical connection | |||||
Connection | Connector: 1 x M12; Contacts: gold-plated |