Product characteristics | |||||||||
---|---|---|---|---|---|---|---|---|---|
Electrical design | PNP | ||||||||
Output function | 2 x OSSD, 1 x PNP | ||||||||
Sensing range [mm] | 12; (with defined actuator) | ||||||||
Housing | rectangular | ||||||||
Dimensions [mm] | 72 x 18 x 25 | ||||||||
Application | |||||||||
Design | uniquely fully coded target | ||||||||
Type of operation | permanent operation | ||||||||
Electrical data | |||||||||
Operating voltage [V] | 20.4…26.4 DC | ||||||||
Rated insulation voltage [V] | 32 | ||||||||
Operating current [mA] | 40…700 | ||||||||
No-load current [mA] | 30 | ||||||||
Current consumption [mA] | < 50 | ||||||||
Protection class | III | ||||||||
Reverse polarity protection | yes | ||||||||
Max. power-on delay time [ms] | 1500 | ||||||||
Outputs | |||||||||
Electrical design | PNP | ||||||||
Output function | 2 x OSSD, 1 x PNP | ||||||||
Max. leakage current [mA] | 0.5 | ||||||||
Permanent current rating of switching output DC [mA] | 50 | ||||||||
Switching frequency DC [Hz] | 1 | ||||||||
Output data | interface type C class 2 | ||||||||
Short-circuit protection | yes | ||||||||
Overload protection | yes | ||||||||
Max. capacitive load CL_max [nF] | 200 | ||||||||
Detection zone | |||||||||
Sensing range [mm] | 12; (with defined actuator) | ||||||||
Safe switching-off distance s(ar) [mm] | 16 | ||||||||
Accuracy / deviations | |||||||||
Hysteresis [%] | 20 | ||||||||
Repeatability analogue output [%] | ≤ 10; (% Sn) | ||||||||
Response times | |||||||||
Response time to safety request [ms] | 160 | ||||||||
Response time when approaching the enable zone [ms] | 600 | ||||||||
Risk time (response time for safety-related faults) [ms] | 10 | ||||||||
Operating conditions | |||||||||
Applications | class C to EN 60654-1 weatherproof application | ||||||||
Ambient temperature [°C] | -25…70 | ||||||||
Note on ambient temperature |
| ||||||||
Ambient temperature [°C] | 10…40 | ||||||||
Note on ambient temperature |
| ||||||||
Max. relative air humidity [%] | briefly: 5…95 %; permanent: 5…70 % | ||||||||
Air pressure [kPa] | 80…106 | ||||||||
Max. height above sea level [m] | 2000 | ||||||||
Ionising radiation | not permissible | ||||||||
Salt spray | no | ||||||||
Protection | IP 67; IP 69K; (protected cable laying) | ||||||||
Safety classification | |||||||||
ISO 13849-1 | category 4, PL e | ||||||||
IEC 62061 | SIL cl 3 | ||||||||
Mission time TM [h] | ≤ 175200 | ||||||||
Mission time TM (additional indication) |
| ||||||||
Safety-related reliability PFHD [1/h] | 1.5E-09 | ||||||||
Mechanical data | |||||||||
Weight [g] | 330 | ||||||||
Housing | rectangular | ||||||||
Mounting | non-flush mountable | ||||||||
Dimensions [mm] | 72 x 18 x 25 | ||||||||
Materials | PA | ||||||||
Tightening torque [Nm] | 0.8…2 | ||||||||
Displays / operating elements | |||||||||
Display |
| ||||||||
Accessories | |||||||||
Accessories (supplied) |
| ||||||||
Remarks | |||||||||
Pack quantity | 1 pcs. | ||||||||
Electrical connection | |||||||||
Connection | Cable: 2 m, PVC; 8 x 0.34 mm² |