Product characteristics | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|
Output signal | switching signal; analogue signal; IO-Link; (configurable) | |||||||||
Measuring range |
| |||||||||
Process connection | Clamp DN50 (2″) DIN 32676 (ISO 2852) | |||||||||
Application | ||||||||||
Special feature | Gold-plated contacts | |||||||||
Application | food and beverage industry | |||||||||
Media | viscous media and liquids with suspended particles; liquids and gases | |||||||||
Medium temperature [°C] | -25…200 | |||||||||
Min. bursting pressure |
| |||||||||
Pressure rating |
| |||||||||
Type of pressure | relative pressure; vacuum | |||||||||
Electrical data | ||||||||||
Min. insulation resistance [MΩ] | 100; (500 V DC) | |||||||||
Protection class | III | |||||||||
Reverse polarity protection | yes | |||||||||
Integrated watchdog | yes | |||||||||
2-wire | ||||||||||
Operating voltage [V] | 20…32 DC | |||||||||
Current consumption [mA] | 3.6…21 | |||||||||
Power-on delay time [s] | 1 | |||||||||
3-wire | ||||||||||
Operating voltage [V] | 18…32 DC | |||||||||
Current consumption [mA] | < 45 | |||||||||
Power-on delay time [s] | 0.5 | |||||||||
Inputs / outputs | ||||||||||
Number of inputs and outputs | Number of digital outputs: 2; Number of analogue outputs: 1 | |||||||||
Outputs | ||||||||||
Total number of outputs | 2 | |||||||||
Output signal | switching signal; analogue signal; IO-Link; (configurable) | |||||||||
Electrical design | PNP/NPN | |||||||||
Number of digital outputs | 2 | |||||||||
Output function | normally open / normally closed; (parameterisable) | |||||||||
Number of analogue outputs | 1 | |||||||||
Analogue current output [mA] | 4…20, invertible; (scalable) | |||||||||
Short-circuit protection | yes | |||||||||
Type of short-circuit protection | pulsed | |||||||||
Overload protection | yes | |||||||||
2-wire | ||||||||||
Max. load [Ω] | 300 | |||||||||
3-wire | ||||||||||
Max. voltage drop switching output DC [V] | 2 | |||||||||
Permanent current rating of switching output DC [mA] | 250 | |||||||||
Switching frequency DC [Hz] | 125 | |||||||||
Max. load [Ω] | (Ub – 10 V) / 20 mA | |||||||||
Measuring/setting range | ||||||||||
Measuring range |
| |||||||||
Set point SP |
| |||||||||
Reset point rP |
| |||||||||
Analogue start point |
| |||||||||
Analogue end point |
| |||||||||
In steps of |
| |||||||||
Factory setting |
| |||||||||
Accuracy / deviations | ||||||||||
Switch point accuracy [% of the span] | < ± 0,2; (Turn down 1:1) | |||||||||
Repeatability [% of the span] | < ± 0,1; (with temperature fluctuations < 10 K; Turn down 1:1) | |||||||||
Characteristics deviation [% of the span] | < ± 0,2; (Turn down 1:1 linearity, incl. hysteresis and repeatability limit value setting to DIN 16086) | |||||||||
Linearity deviation [% of the span] | < ± 0,15; (Turn down 1:1) | |||||||||
Hysteresis deviation [% of the span] | < ± 0,15; (Turn down 1:1) | |||||||||
Long-term stability [% of the span] | < ± 0,1; (Turn down 1:1; per year) | |||||||||
Temperature coefficient zero point [% of the span / 10 K] | < ± 0,3; (0…200 °C) | |||||||||
Temperature coefficient span [% of the span / 10 K] | < ± 0,15; (0…200 °C) | |||||||||
Response times | ||||||||||
Damping for the switching output dAP [s] | 0…30 | |||||||||
Damping for the analogue output dAA [s] | 0.01…99.99 | |||||||||
2-wire | ||||||||||
Step response time analogue output [ms] | 45 | |||||||||
3-wire | ||||||||||
Min. response time of switching output (dAP) [ms] | 3 | |||||||||
Step response time analogue output [ms] | 7 | |||||||||
Interfaces | ||||||||||
Communication interface | IO-Link | |||||||||
Transmission type | COM2 (38,4 kBaud) | |||||||||
IO-Link revision | 1.0 | |||||||||
SDCI standard | IO-Link Communication Specification, Version 1.0, January 2009, Ordner No: 10.002 | |||||||||
Profiles | no profile | |||||||||
SIO mode | yes | |||||||||
Required master port type | A | |||||||||
Process data analogue | 1 | |||||||||
Process data binary | 2 | |||||||||
Min. process cycle time [ms] | 2.3 | |||||||||
Supported DeviceIDs |
| |||||||||
Operating conditions | ||||||||||
Ambient temperature [°C] | -25…80 | |||||||||
Note on ambient temperature |
| |||||||||
Ambient temperature [°C] | -25…65 | |||||||||
Note on ambient temperature |
| |||||||||
Storage temperature [°C] | -25…100 | |||||||||
Protection | IP 67; IP 68; IP 69K | |||||||||
Mechanical data | ||||||||||
Weight [g] | 1047.5 | |||||||||
Materials | stainless steel (1.4404 / 316L); stainless steel (1.4435 / 316L); PBT; PEI; PFA | |||||||||
Materials (wetted parts) | stainless steel (1.4435 / 316L) | |||||||||
Min. pressure cycles | 10 million | |||||||||
Process connection | Clamp DN50 (2″) DIN 32676 (ISO 2852) | |||||||||
Surface characteristics Ra/Rz of the wetted parts | < 0.38 / – | |||||||||
Fill fluid for pressure transfer | NEOBEE (food grade, FDA compliant) | |||||||||
Diaphragm diameter [mm] | 47.5 | |||||||||
Displays / operating elements | ||||||||||
Display |
| |||||||||
Display unit | mbar; kPa; psi; inH2O; mWS; % of the span | |||||||||
Remarks | ||||||||||
Pack quantity | 1 pcs. | |||||||||
Electrical connection | ||||||||||
Connector: 1 x M12; Contacts: gold-plated |