Product characteristics | |||||||||
---|---|---|---|---|---|---|---|---|---|
Output signal | switching signal; analogue signal; (configurable) | ||||||||
Measuring range [bar] | 0…600 | ||||||||
Process connection | homogeniser connection | ||||||||
Application | |||||||||
Special feature | Gold-plated contacts | ||||||||
Application | food and beverage industry | ||||||||
Media | liquids and gases | ||||||||
Conditionally suitable for | For gaseous media the application is limited to max. 25 bar. | ||||||||
Medium temperature [°C] | -25…100; (145 max 1h) | ||||||||
Min. bursting pressure [bar] | 1200 | ||||||||
Pressure rating [bar] | 800 | ||||||||
Type of pressure | relative pressure | ||||||||
Electrical data | |||||||||
Operating voltage [V] | 20…30 DC | ||||||||
Current consumption [mA] | < 65 | ||||||||
Min. insulation resistance [MΩ] | 100; (500 V DC) | ||||||||
Protection class | III | ||||||||
Reverse polarity protection | yes | ||||||||
Power-on delay time [s] | 0.3 | ||||||||
Integrated watchdog | yes | ||||||||
Inputs / outputs | |||||||||
Number of inputs and outputs | Number of digital outputs: 2; Number of analogue outputs: 1 | ||||||||
Outputs | |||||||||
Total number of outputs | 2 | ||||||||
Output signal | switching signal; analogue signal; (configurable) | ||||||||
Electrical design | PNP/NPN | ||||||||
Number of digital outputs | 2 | ||||||||
Output function | normally open / normally closed; (parameterisable) | ||||||||
Max. voltage drop switching output DC [V] | 2 | ||||||||
Permanent current rating of switching output DC [mA] | 250 | ||||||||
Switching frequency DC [Hz] | < 170 | ||||||||
Number of analogue outputs | 1 | ||||||||
Analogue current output [mA] | 4…20; (scalable 1:4) | ||||||||
Max. load [Ω] | (Ub – 10 V) / 20 mA | ||||||||
Analogue voltage output [V] | 0…10; (scalable 1:4) | ||||||||
Min. load resistance [Ω] | 2000 | ||||||||
Short-circuit protection | yes | ||||||||
Type of short-circuit protection | pulsed | ||||||||
Overload protection | yes | ||||||||
Measuring/setting range | |||||||||
Measuring range [bar] | 0…600 | ||||||||
Set point SP [bar] | 6…600 | ||||||||
Reset point rP [bar] | 3…597 | ||||||||
Analogue start point [bar] | 0…240 | ||||||||
Analogue end point [bar] | 150…600 | ||||||||
In steps of [bar] | 3 | ||||||||
Accuracy / deviations | |||||||||
Switch point accuracy [% of the span] | < ± 1,0; (Turn down 1:1) | ||||||||
Repeatability [% of the span] | < ± 0,25; (with temperature fluctuations < 10 K; Turn down 1:1) | ||||||||
Characteristics deviation [% of the span] | < ± 1,0; (Turn down 1:1 linearity, incl. hysteresis and repeatability limit value setting to DIN 16086) | ||||||||
Linearity deviation [% of the span] | < ± 0,5; (Turn down 1:1) | ||||||||
Hysteresis deviation [% of the span] | < ± 1,0; (Turn down 1:1) | ||||||||
Long-term stability [% of the span] | < ± 0,25; (Turn down 1:1; per year) | ||||||||
Temperature coefficient zero point [% of the span / 10 K] | < ± 0,2; (0…80 °C) | ||||||||
Temperature coefficient span [% of the span / 10 K] | < ± 0,2; (0…80 °C) | ||||||||
Response times | |||||||||
Response time [ms] | < 3 | ||||||||
Damping for the switching output dAP [s] | 0…4 | ||||||||
Damping for the analogue output dAA in steps [s] | 0 – 0; 1 – 0; 5 – 2 | ||||||||
Max. response time analogue output [ms] | 3 | ||||||||
Software / programming | |||||||||
Parameter setting options | hysteresis / window; normally open / normally closed; switching logic; current/voltage output; Damping; adaptation of displayed values; display can be rotated and switched off; Display unit; zero point; span | ||||||||
Operating conditions | |||||||||
Ambient temperature [°C] | -25…80 | ||||||||
Storage temperature [°C] | -40…100 | ||||||||
Protection | IP 67 | ||||||||
Mechanical data | |||||||||
Weight [g] | 384 | ||||||||
Materials | stainless steel (1.4301 / 304); stainless steel (1.4404 / 316L); PC; PBT; PA; FKM; EPDM/X | ||||||||
Materials (wetted parts) | stainless steel (1.4404 / 316L); ceramics (99.9 % Al2O3); FKM | ||||||||
Min. pressure cycles | 50 million | ||||||||
Process connection | homogeniser connection | ||||||||
Displays / operating elements | |||||||||
Display |
| ||||||||
Display unit | bar; psi; MPa | ||||||||
Remarks | |||||||||
Pack quantity | 1 pcs. | ||||||||
Electrical connection | |||||||||
Connection | Connector: 1 x M12; Contacts: gold-plated |