Product characteristics | |||||||||
---|---|---|---|---|---|---|---|---|---|
Number of inputs and outputs | Number of analogue outputs: 2 | ||||||||
Measuring range |
| ||||||||
Process connection | threaded connection G 2 DN50 flat seal | ||||||||
Application | |||||||||
Special feature | Gold-plated contacts | ||||||||
Application | empty pipe detection; for industrial applications | ||||||||
Installation | connection to pipe by means of an adapter | ||||||||
Media | conductive liquids; water; hydrous media | ||||||||
Note on media |
| ||||||||
Medium temperature |
| ||||||||
Pressure rating [bar] | 16 | ||||||||
Pressure rating [Mpa] | 1.6 | ||||||||
Pressure rating [psi] | 232 | ||||||||
MAWP (for applications according to CRN) [bar] | 16.5 | ||||||||
Electrical data | |||||||||
Operating voltage [V] | 18…32 DC; (according to EN 50178 SELV/PELV) | ||||||||
Current consumption [mA] | < 150 | ||||||||
Protection class | III | ||||||||
Reverse polarity protection | yes | ||||||||
Power-on delay time [s] | 5 | ||||||||
Inputs / outputs | |||||||||
Number of inputs and outputs | Number of analogue outputs: 2 | ||||||||
Outputs | |||||||||
Total number of outputs | 2 | ||||||||
Output signal | analogue signal | ||||||||
Number of analogue outputs | 2 | ||||||||
Analogue current output [mA] | 4…20; (≤ 22 mA; scalable) | ||||||||
Max. load [Ω] | 500 | ||||||||
Measuring/setting range | |||||||||
Measuring range |
| ||||||||
Display range |
| ||||||||
Resolution |
| ||||||||
Analogue start point ASP |
| ||||||||
Analogue end point AEP |
| ||||||||
Low flow cut-off LFC |
| ||||||||
In steps of |
| ||||||||
Measuring dynamics | 1:120 | ||||||||
Temperature monitoring | |||||||||
Measuring range |
| ||||||||
Display range |
| ||||||||
Resolution |
| ||||||||
Analogue start point |
| ||||||||
Analogue end point |
| ||||||||
In steps of |
| ||||||||
Accuracy / deviations | |||||||||
Flow monitoring | |||||||||
Accuracy (in the measuring range) | ± (0,8 % MW + 0,5 % MEW) | ||||||||
Repeatability | ± 0,2% MEW | ||||||||
Temperature monitoring | |||||||||
Temperature drift | ± 0,0333 °C / K; ± 0,0599 °F / K | ||||||||
Accuracy [K] | ± 1 (25 °C; Q > 15 l/min) / ± 1 (77 °F; Q > 4 gpm) | ||||||||
Response times | |||||||||
Flow monitoring | |||||||||
Response time [s] | 0.35; (dAP = 0) | ||||||||
Damping for the switching output dAP [s] | 0…5 | ||||||||
Temperature monitoring | |||||||||
Dynamic response T05 / T09 [s] | T09 = 3 (Q > 15 l/min) / T09 = 3 (Q > 4 gpm) | ||||||||
Software / programming | |||||||||
Parameter setting options | display can be deactivated; Display unit; empty pipe detection | ||||||||
Operating conditions | |||||||||
Ambient temperature |
| ||||||||
Storage temperature |
| ||||||||
Protection | IP 65; IP 67 | ||||||||
Mechanical data | |||||||||
Weight [g] | 3147 | ||||||||
Materials | stainless steel (1.4404 / 316L); stainless steel (1.4571/316Ti ); PEI; FKM; PBT-GF20; TPE-U | ||||||||
Materials (wetted parts) | stainless steel (1.4404 / 316L); stainless steel (1.4571/316Ti ); PEEK; NBR reinforced fibre; FKM | ||||||||
Process connection | threaded connection G 2 DN50 flat seal | ||||||||
Displays / operating elements | |||||||||
Display |
| ||||||||
Display unit | l/min; m³/h; gpm; gph; °C; °F | ||||||||
Accessories | |||||||||
Accessories (supplied) |
| ||||||||
Remarks | |||||||||
Remarks |
| ||||||||
Pack quantity | 1 pcs. | ||||||||
Electrical connection | |||||||||
Connection | Connector: 1 x M12; Contacts: gold-plated |