Product characteristics | |||||
---|---|---|---|---|---|
Number of inputs and outputs | Number of digital outputs: 2 | ||||
Measuring range |
| ||||
Process connection | threaded connection G 1/4 external thread | ||||
Installation length EL [mm] | 39 | ||||
Application | |||||
Special feature | Gold-plated contacts | ||||
Measuring element | 1 x Pt 1000; (to DIN EN 60751, class B) | ||||
Media | liquids and gases | ||||
Medium temperature [°C] | -25…125; (145 max. 1 h) | ||||
Pressure rating [bar] | 300 | ||||
Minimum installation depth [mm] | 15 | ||||
Electrical data | |||||
Operating voltage [V] | 9.6…32 DC; (operating voltage “supply class 2” according to cULus) | ||||
Current consumption [mA] | < 30 | ||||
Protection class | III | ||||
Reverse polarity protection | yes | ||||
Power-on delay time [s] | 0.5 | ||||
Inputs / outputs | |||||
Number of inputs and outputs | Number of digital outputs: 2 | ||||
Outputs | |||||
Total number of outputs | 2 | ||||
Output signal | switching signal | ||||
Electrical design | PNP | ||||
Number of digital outputs | 2 | ||||
Output function | complementary | ||||
Max. voltage drop switching output DC [V] | 2 | ||||
Permanent current rating of switching output DC [mA] | 500 | ||||
Short-circuit protection | yes | ||||
Type of short-circuit protection | pulsed | ||||
Overload protection | yes | ||||
Measuring/setting range | |||||
Probe length L [mm] | 25 | ||||
Measuring range |
| ||||
Set point SP |
| ||||
Reset point rP |
| ||||
Accuracy / deviations | |||||
Temperature drift per 10 K [K] | 0.1 | ||||
Repeatability [K] | ± 0,1 | ||||
Setting accuracy [K] | ± 3 | ||||
Response times | |||||
Dynamic response T05 / T09 [s] | 1 / 3; (to DIN EN 60751) | ||||
Software / programming | |||||
Adjustment of the switch point | setting rings | ||||
Operating conditions | |||||
Ambient temperature [°C] | -25…70 | ||||
Storage temperature [°C] | -40…100 | ||||
Protection | IP 67 | ||||
Mechanical data | |||||
Weight [g] | 102.5 | ||||
Materials | stainless steel (1.4404 / 316L); PC; PBT; FKM | ||||
Materials (wetted parts) | stainless steel (1.4404 / 316L); FKM | ||||
Process connection | threaded connection G 1/4 external thread | ||||
Installation length EL [mm] | 39 | ||||
Displays / operating elements | |||||
Display |
| ||||
With scale | yes | ||||
Remarks | |||||
Remarks |
| ||||
Notes | discontinued article | ||||
Pack quantity | 1 pcs. | ||||
Electrical connection | |||||
Connection | Connector: 1 x M12; Contacts: gold-plated |