Product characteristics | |||
---|---|---|---|
Measuring range |
| ||
Process connection | bolt-on sensor 12,5 x 8,7 x 47 mm | ||
Application | |||
Measuring element | 1 x Pt 100; (to DIN EN 60751, class A) | ||
Installation | surface mount RTD for solid bodies | ||
Electrical data | |||
Insulation rating [V] | 500 | ||
Protection class | III | ||
Measuring/setting range | |||
Measuring range |
| ||
Accuracy / deviations | |||
Accuracy [K] | ± (0,15 K + 0,002 x |t|) | ||
Response times | |||
Dynamic response T05 / T09 [s] | 12 / 39; (values for a flat aluminium surface (anodised) using a conductive heat paste; reference values for moving water : 10 / 24 (< 0,1 m/s)) | ||
Operating conditions | |||
Protection | IP 67 | ||
Mechanical data | |||
Weight [g] | 101.4 | ||
Housing | bolt-on sensor | ||
Dimensions [mm] | 12.5 x 8.7 x 47 | ||
Materials | stainless steel (1.4303 / 305 / 308); copper nickel-plated | ||
Process connection | bolt-on sensor 12,5 x 8,7 x 47 mm | ||
Remarks | |||
Pack quantity | 1 pcs. | ||
Electrical connection | |||
Connection | Cable: 2 m, PUR, Ø 4.9 mm; with wire end ferrules; 4 x 0.34 mm² (42 x Ø 0.1 mm ) |