Product characteristics | |||||||
---|---|---|---|---|---|---|---|
Number of inputs and outputs | Number of digital outputs: 2; Number of analogue outputs: 1 | ||||||
Measuring range [l/min] | 0…10 | ||||||
Application | |||||||
Special feature | Gold-plated contacts | ||||||
Installation | T-pieces; ((DIN 2353): QL 18-18-18 (NW 15 mm) / QL 22-18-22 (NW 19 mm) / QL 28-18-28 (NW 24 mm)) | ||||||
Media | water | ||||||
Medium temperature [°C] | 0…80 | ||||||
Pressure rating [bar] | 30 | ||||||
Electrical data | |||||||
Operating voltage [V] | 20…28 DC | ||||||
Current consumption [mA] | < 80 | ||||||
Protection class | III | ||||||
Reverse polarity protection | yes | ||||||
Power-on delay time [s] | 10 | ||||||
Inputs / outputs | |||||||
Number of inputs and outputs | Number of digital outputs: 2; Number of analogue outputs: 1 | ||||||
Outputs | |||||||
Total number of outputs | 2 | ||||||
Output signal | switching signal; analogue signal; (configurable) | ||||||
Electrical design | PNP/NPN | ||||||
Number of digital outputs | 2 | ||||||
Output function | normally open / normally closed; (parameterisable) | ||||||
Max. voltage drop switching output DC [V] | 2 | ||||||
Permanent current rating of switching output DC [mA] | 250; (per output) | ||||||
Number of analogue outputs | 1 | ||||||
Analogue current output [mA] | 4…20; (scalable) | ||||||
Max. load [Ω] | 500 | ||||||
Analogue voltage output [V] | 0…10; (scalable) | ||||||
Min. load resistance [Ω] | 2000 | ||||||
Short-circuit protection | yes | ||||||
Type of short-circuit protection | pulsed | ||||||
Overload protection | yes | ||||||
Measuring/setting range | |||||||
Measuring range [l/min] | 0…10 | ||||||
Display range [l/min] | 0…12 | ||||||
Set point SP [l/min] | 0.1…12 | ||||||
Reset point rP [l/min] | 0…11.9 | ||||||
Analogue start point ASP [l/min] | 0…8 | ||||||
Analogue end point AEP [l/min] | 4…12 | ||||||
In steps of [l/min] | 0.1 | ||||||
Accuracy / deviations | |||||||
Flow monitoring | |||||||
Repeatability [% of the measured value] | 3 (Q < 30%) / 7 (Q < 100%) | ||||||
Temperature gradient [K/min] | 200 | ||||||
Accuracy (in the measuring range) | ± 10 | ||||||
Response times | |||||||
Flow monitoring | |||||||
Response time [s] | 5; (10%…90%) | ||||||
Delay time programmable dS, dr [s] | 0…50 | ||||||
Software / programming | |||||||
Parameter setting options | hysteresis / window; normally open / normally closed; switching logic; current/voltage output; inside pipe diameter; start-up delay; adaptation of displayed values; display can be rotated and switched off; Display unit | ||||||
Operating conditions | |||||||
Ambient temperature [°C] | -20…60 | ||||||
Protection | IP 67 | ||||||
Mechanical data | |||||||
Weight [g] | 330.5 | ||||||
Materials | stainless steel (1.4404 / 316L); PBT; PC; PA; EPDM/X; FKM | ||||||
Materials (wetted parts) | stainless steel (1.4404 / 316L); O-ring: FKM 70 Shore A | ||||||
Displays / operating elements | |||||||
Display |
| ||||||
Display unit | l/min; gpm; l/h; gph; m³/h | ||||||
Remarks | |||||||
Remarks |
| ||||||
Pack quantity | 1 pcs. | ||||||
Electrical connection | |||||||
Connection | Connector: 1 x M12; Contacts: gold-plated |