Product characteristics | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
Number of inputs and outputs | Number of digital outputs: 2; Number of analogue outputs: 1 | ||||||||||
Measuring range |
| ||||||||||
Process connection | threaded connection R 1/2 DN15 | ||||||||||
Application | |||||||||||
Application | for industrial applications | ||||||||||
Media | compressed air | ||||||||||
Note on media |
| ||||||||||
Medium temperature [°C] | 0…60 | ||||||||||
Pressure rating [bar] | 16 | ||||||||||
Pressure rating [Mpa] | 1.6 | ||||||||||
MAWP (for applications according to CRN) [bar] | 16 | ||||||||||
Electrical data | |||||||||||
Operating voltage [V] | 18…30 DC; (according to EN 50178 SELV/PELV) | ||||||||||
Current consumption [mA] | < 110 | ||||||||||
Protection class | III | ||||||||||
Reverse polarity protection | yes | ||||||||||
Power-on delay time [s] | 1 | ||||||||||
Inputs / outputs | |||||||||||
Number of inputs and outputs | Number of digital outputs: 2; Number of analogue outputs: 1 | ||||||||||
Outputs | |||||||||||
Total number of outputs | 2 | ||||||||||
Output signal | switching signal; analogue signal; pulse signal; IO-Link; (configurable) | ||||||||||
Electrical design | PNP | ||||||||||
Number of digital outputs | 2 | ||||||||||
Output function | normally open / normally closed; (parameterisable) | ||||||||||
Max. voltage drop switching output DC [V] | 2 | ||||||||||
Permanent current rating of switching output DC [mA] | 250; (per output) | ||||||||||
Number of analogue outputs | 1 | ||||||||||
Analogue current output [mA] | 4…20; (scalable) | ||||||||||
Max. load [Ω] | 500 | ||||||||||
Pulse output | consumed quantity meter | ||||||||||
Short-circuit protection | yes | ||||||||||
Type of short-circuit protection | pulsed | ||||||||||
Overload protection | yes | ||||||||||
Measuring/setting range | |||||||||||
Measuring range |
| ||||||||||
Display range |
| ||||||||||
Set point SP |
| ||||||||||
Reset point rP |
| ||||||||||
Analogue start point ASP |
| ||||||||||
Analogue end point AEP |
| ||||||||||
In steps of |
| ||||||||||
Volumetric flow quantity monitoring | |||||||||||
Pulse value | 0.001…1000000 m³ | ||||||||||
In steps of | 0.001 m³ | ||||||||||
Pulse length [s] | 0,02…2 | ||||||||||
Temperature monitoring | |||||||||||
Measuring range [°C] | 0…60 | ||||||||||
Display range [°C] | -12…72 | ||||||||||
Accuracy / deviations | |||||||||||
Flow monitoring | |||||||||||
Repeatability [% of the measured value] | ± 1,5 | ||||||||||
Accuracy (in the measuring range) | ± (3 % MW + 0,3 % MEW) / ± (6 % MW + 0,6 % MEW); (class 141 / ; class 344; conditions: installation to DIN ISO 2533; installation in pipes: DN15) | ||||||||||
Temperature monitoring | |||||||||||
Accuracy [K] | ± 2; (medium flow in the limit area of the flow measurement range) | ||||||||||
Response times | |||||||||||
Flow monitoring | |||||||||||
Response time [s] | 0.1; (dAP = 0) | ||||||||||
Damping for the switching output dAP in steps [s] | 0 – 0,2 – 0,4 – 0,6 – 0,8 – 1 | ||||||||||
Software / programming | |||||||||||
Parameter setting options | Flow monitoring; quantity meter; Preset counter; Temperature monitoring; hysteresis / window; normally open / normally closed; current/pulse output; display can be rotated and switched off; Display unit; totaliser | ||||||||||
Interfaces | |||||||||||
Communication interface | IO-Link | ||||||||||
Transmission type | COM2 (38,4 kBaud) | ||||||||||
IO-Link revision | 1.1 | ||||||||||
SDCI standard | IEC 61131-9 CDV | ||||||||||
Profiles | no profile | ||||||||||
SIO mode | yes | ||||||||||
Required master port type | A | ||||||||||
Process data analogue | 3 | ||||||||||
Process data binary | 2 | ||||||||||
Min. process cycle time [ms] | 4.1 | ||||||||||
Supported DeviceIDs |
| ||||||||||
Operating conditions | |||||||||||
Ambient temperature [°C] | 0…60 | ||||||||||
Storage temperature [°C] | -20…85 | ||||||||||
Max. relative air humidity [%] | 90 | ||||||||||
Protection | IP 65 | ||||||||||
Mechanical data | |||||||||||
Weight [g] | 942.5 | ||||||||||
Materials | PBT-GF20; NBR; PC; stainless steel (1.4301 / 304); PTFE; brass coated; FKM; aluminium powder-coated | ||||||||||
Materials (wetted parts) | stainless steel (1.4301 / 304); FKM; ceramics glass passivated; PEEK GF30; polyester; aluminium | ||||||||||
Tightening torque [Nm] | 50 | ||||||||||
Process connection | threaded connection R 1/2 DN15 | ||||||||||
Displays / operating elements | |||||||||||
Display |
| ||||||||||
Remarks | |||||||||||
Remarks |
| ||||||||||
Pack quantity | 1 pcs. | ||||||||||
Electrical connection | |||||||||||
Connection | Connector: 1 x M12 |