Product characteristics | |
---|---|
Electrical design | NAMUR |
Output function | normally closed |
Housing | rectangular |
Dimensions [mm] | 8 x 15 x 11 |
Electrical data | |
Connection to switching amplifiers | yes |
Switching amplifiers | connection to certified intrinsically safe circuits with the max. values: U = 15 V / I = 50 mA / P = 120 mW |
Nominal voltage DC [V] | 8.2; (1kΩ) |
Supply voltage DC [V] | 5…25; (when used outside the hazardous area) |
Current consumption [mA] | < 1.2; (disabled; conductive: > 2,1) |
Protection class | III |
Outputs | |
Electrical design | NAMUR |
Output function | normally closed |
Switching frequency DC [Hz] | 5000 |
Detection zone | |
Insertion depth (from the side) [mm] | 5…7 |
Operating conditions | |
Ambient temperature [°C] | -40…100 |
Protection | IP 67 |
Safety classification | |
Max. internal capacitance [nF] | 150 |
Max. internal inductance [µH] | 120 |
Mechanical data | |
Weight [g] | 30 |
Housing | rectangular |
Dimensions [mm] | 8 x 15 x 11 |
Slot width [mm] | 2 |
Materials | PBT |
Remarks | |
Pack quantity | 1 pcs. |
Electrical connection | |
Connection | Cable: 0.5 m; 2 x 0.06 mm², PTFE |