Product characteristics | |||||||
---|---|---|---|---|---|---|---|
Output signal | switching signal | ||||||
Measuring range |
| ||||||
Process connection | threaded connection G 1/8 internal thread | ||||||
Application | |||||||
Special feature | Gold-plated contacts | ||||||
Application | for industrial applications | ||||||
Media | compressed air | ||||||
Conditionally suitable for | other media on request | ||||||
Medium temperature [°C] | 0…60 | ||||||
Min. bursting pressure |
| ||||||
Pressure rating |
| ||||||
Type of pressure | relative pressure; vacuum | ||||||
Electrical data | |||||||
Operating voltage [V] | 18…36 DC; (according to EN 50178 SELV/PELV) | ||||||
Current consumption [mA] | < 50 | ||||||
Min. insulation resistance [MΩ] | 100; (500 V DC) | ||||||
Protection class | III | ||||||
Reverse polarity protection | yes | ||||||
Overvoltage protection | yes; (< 40 V) | ||||||
Power-on delay time [s] | 0.3 | ||||||
Integrated watchdog | yes | ||||||
Inputs / outputs | |||||||
Number of inputs and outputs | Number of digital outputs: 2 | ||||||
Outputs | |||||||
Total number of outputs | 2 | ||||||
Output signal | switching signal | ||||||
Electrical design | PNP/NPN | ||||||
Number of digital outputs | 2 | ||||||
Output function | normally open / normally closed; (parameterisable) | ||||||
Max. voltage drop switching output DC [V] | 2 | ||||||
Permanent current rating of switching output DC [mA] | 250 | ||||||
Switching frequency DC [Hz] | < 170 | ||||||
Short-circuit protection | yes | ||||||
Type of short-circuit protection | pulsed | ||||||
Measuring/setting range | |||||||
Measuring range |
| ||||||
Set point SP |
| ||||||
Reset point rP |
| ||||||
In steps of |
| ||||||
Factory setting |
| ||||||
Accuracy / deviations | |||||||
Switch point accuracy [% of the span] | < ± 0,5 | ||||||
Repeatability [% of the span] | < ± 0,1; (with temperature fluctuations < 10 K) | ||||||
Characteristics deviation [% of the span] | < ± 0,25 (BFSL) / < ± 0,5 (LS); (BFSL = Best Fit Straight Line; LS = limit value setting) | ||||||
Hysteresis deviation [% of the span] | < ± 0,25 | ||||||
Long-term stability [% of the span] | < ± 0,05; (per 6 months) | ||||||
Temperature coefficient zero point [% of the span / 10 K] | 0,2; (0…60 °C) | ||||||
Temperature coefficient span [% of the span / 10 K] | 0,2; (0…60 °C) | ||||||
Response times | |||||||
Delay time programmable dS, dr [s] | 0; 0,2…50 | ||||||
Software / programming | |||||||
Parameter setting options | hysteresis / window; normally open / normally closed; diagnostic function; switching logic; switch-on/switch-off delay; Damping; Display unit | ||||||
Operating conditions | |||||||
Ambient temperature [°C] | -25…85 | ||||||
Storage temperature [°C] | -25…85 | ||||||
Protection | IP 67 | ||||||
Mechanical data | |||||||
Weight [g] | 173.5 | ||||||
Materials | stainless steel (1.4301 / 304); PPS; PC; PBT; PEI; FKM | ||||||
Materials (wetted parts) | stainless steel (1.4567 / 304Cu); brass; FKM; PPS; silicon (coated) | ||||||
Min. pressure cycles | 50 million | ||||||
Process connection | threaded connection G 1/8 internal thread | ||||||
Displays / operating elements | |||||||
Display |
| ||||||
Accessories | |||||||
Accessories (optional) |
| ||||||
Remarks | |||||||
Pack quantity | 1 pcs. | ||||||
Electrical connection | |||||||
Connector: 1 x M12; Contacts: gold-plated |