Product characteristics | |||
---|---|---|---|
Output function | normally open | ||
Sensing range [mm] | 2 | ||
Housing | rectangular | ||
Dimensions [mm] | 28 x 10 x 16 | ||
Electrical data | |||
Frequency AC [Hz] | 45…65 | ||
Operating voltage [V] | 20…140 AC / 10…140 DC | ||
Protection class | II | ||
Reverse polarity protection | no | ||
Outputs | |||
Output function | normally open | ||
Max. voltage drop switching output DC [V] | 5 | ||
Max. voltage drop switching output AC [V] | 5 | ||
Minimum load current [mA] | 5 | ||
Max. leakage current [mA] | 0.8 | ||
Permanent current rating of switching output AC [mA] | 200 | ||
Permanent current rating of switching output DC [mA] | 200 | ||
Short-time current rating of switching output [mA] | 900; (20 ms / 0,5 Hz) | ||
Switching frequency AC [Hz] | 25 | ||
Switching frequency DC [Hz] | 25 | ||
Short-circuit protection | no | ||
Overload protection | no | ||
Detection zone | |||
Sensing range [mm] | 2 | ||
Real sensing range Sr [mm] | 2 ± 10 % | ||
Operating distance [mm] | 0…1.6 | ||
Accuracy / deviations | |||
Correction factor | steel: 1 / stainless steel: 0.9 / brass: 0.8 / aluminium: 0.5 / copper: 0.46 | ||
Hysteresis [% of Sr] | 1…15 | ||
Switch point drift [% of Sr] | -10…10 | ||
Operating conditions | |||
Ambient temperature [°C] | -20…80 | ||
Protection | IP 67 | ||
Mechanical data | |||
Weight [g] | 15 | ||
Housing | rectangular | ||
Mounting | flush mountable | ||
Dimensions [mm] | 28 x 10 x 16 | ||
Materials | PBT | ||
Tightening torque [Nm] | < 0.5; (with washer) | ||
Displays / operating elements | |||
Display |
| ||
Electrical connection | |||
Required protection | miniature fuse to IEC60127-2 sheet 1; ≤ 2 A; fast acting | ||
Remarks | |||
Remarks |
| ||
Pack quantity | 1 pcs. | ||
Electrical connection | |||
Connection | Cable: 0.3 m, PVC; 2 x 0.25 mm² |